Al-Halhouli, Ala’aldeen and Al-Ghussain, Loiy and El Bouri, Saleem and Habash, Fuad and Liu, Haipeng and Zheng, Dingchang (2020) Clinical Evaluation of Stretchable and Wearable Inkjet-Printed Strain Gauge Sensor for Respiratory Rate Monitoring at Different Body Postures. Applied Sciences, 10 (2). p. 480. ISSN 2076-3417

[img]
Preview
Text
Published Version
Available under the following license: Creative Commons Attribution Non-commercial No Derivatives.

Download (2MB) | Preview
Official URL: http://dx.doi.org/10.3390/app10020480

Abstract

Respiratory rate (RR) is a vital sign with continuous, convenient, and accurate measurement which is difficult and still under investigation. The present study investigates and evaluates a stretchable and wearable inkjet-printed strain gauge sensor (IJP) to estimate the RR continuously by detecting the respiratory volume change in the chest area. As the volume change could cause different strain changes at different body postures, this study aims to investigate the accuracy of the IJP RR sensor at selected postures. The evaluation was performed twice on 15 healthy male subjects (mean ± SD of age: 24 ± 1.22 years). The RR was simultaneously measured in breaths per minute (BPM) by the IJP RR sensor and a reference RR sensor (e-Health nasal thermal sensor) at each of the five body postures namely standing, sitting at 90°, Flower’s position at 45°, supine, and right lateral recumbent. There was no significant difference in measured RR between IJP and reference sensors, between two trials, or between different body postures (all p > 0.05). Body posture did not have any significant effect on the difference of RR measurements between IJP and the reference sensors (difference <0.01 BPM for each measurement in both trials). The IJP sensor could accurately measure the RR at different body postures, which makes it a promising, simple, and user-friendly option for clinical and daily uses.

Item Type: Journal Article
Keywords: inkjet printing, respiratory rate, strain gauge, stretchable and wearable sensors, silver nanoparticles, clinical evaluation, body posture
Faculty: Faculty of Health, Education, Medicine & Social Care
SWORD Depositor: Symplectic User
Depositing User: Symplectic User
Date Deposited: 10 Jan 2020 14:28
Last Modified: 24 Apr 2020 15:46
URI: http://arro.anglia.ac.uk/id/eprint/705085

Actions (login required)

Edit Item Edit Item