Anglia Ruskin Research Online (ARRO)
Browse

File(s) not publicly available

Reliability of a wearable sweat rate monitor and routine sweat analysis techniques under heat stress in females

journal contribution
posted on 2023-07-26, 14:49 authored by Rebecca Relf, Ashley Willmott, Melanie S. Flint, Louisa Beale, Neil Maxwell
Introduction: The aim of the study was to evaluate the reliability of five different sweat analysis techniques which measure; whole body sweat rate [WBSR], local sweat rate [LSR] (via technical absorbent [TA] method and KuduSmart® monitor), sweat conductivity [SC] and sweat gland activation [SGA] in a female population when exercising moderately under heat stress. Methods: Fourteen females (age; 26 ± 7 years, body mass; 66.5 ± 7.6 kg, height; 167.1 ± 6.4 cm) completed a preliminary threshold walking test (to determine exercise intensity) and two main trials, separated by 2 days. Main trials consisted of 30-min seated rest in the environmental chamber (35 °C, 50% relative humidity) in an upper body sauna-suit, before its removal, and walking at a moderate intensity (4 metabolic equivalents) for 30-min (speeds ranged from 4.8 to 6.5 km h−1). WBSR was measured via nude mass pre and post exercise. The TA and Tegaderm patches (for sweat sodium chloride) were placed on the back, forearm and chest for the entire 60-min, replicated for all participants for both trials. SGA was assessed following the 60-min trial and the KuduSmart® monitor was placed on the left arm for the 30-min of exercise. Results: WBSR, LSR methods and SC demonstrated no difference between trials (p > 0.05), good agreement (within limits), strong correlations (r ≥ 0.88) and low typical error of measurements [TEM] (< 0.04 L min−1, 0.13 mg min−1 cm−2 and 8 mmol L−1, respectively). SGA method showed moderate intra-class correlation (r = 0.80), with high TEM (5 glands) and large limits of agreement. Conclusion: Sudomotor function is reliable, as demonstrated by good reliability, small TEM and strong correlations. The use of these sweat techniques is appropriate and practical in females who are exercising at moderate intensity under heat stress, and so, may aid future interventions. SGA shows larger variation and should be used with caution.

History

Refereed

  • Yes

Volume

79

Page range

209-217

Publication title

Journal of Thermal Biology

ISSN

0306-4565

Publisher

Elsevier

Language

  • other

Legacy posted date

2019-11-22

Legacy Faculty/School/Department

Faculty of Science & Engineering

Note

.

Usage metrics

    ARU Outputs

    Categories

    No categories selected

    Licence

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC