Anglia Ruskin Research Online (ARRO)
Browse

File(s) not publicly available

The In Vivo Pericapsular Tissue Response to Modern Polyurethane Breast Implants

journal contribution
posted on 2023-07-26, 14:39 authored by James D. Frame, Dia Kamel, Marcelo Olivan, Henrique Cintra
Polyurethane breast implants were first introduced by Ashley (Plast Reconstr Surg 45:421–424, 1970), with the intention of trying to reduce the high incidence of capsular contracture associated with smooth shelled, high gel bleed, silicone breast implants. The sterilization of the polyurethane foam in the early days was questionable. More recently, ethylene oxide (ETO)-sterilized polyurethane has been used in the manufacturing process and this has been shown to reduce the incidence of biofilm. The improved method of attachment of polyurethane onto the underlying high cohesive gel, barrier shell layered, silicone breast implants also encourages bio-integration. Polyurethane covered, cohesive gel, silicone implants have also been shown to reduce the incidence of other problems commonly associated with smooth or textured silicone implants, especially with reference to displacement, capsular contracture, seroma, reoperation, biofilm and implant rupture. Since the introduction of the conical polyurethane implant (Silimed, Brazil) into the United Kingdom in 2009 (Eurosurgical, UK), we have had the opportunity to review histology taken from the capsules of polyurethane implants in three women ranging from a few months to over 3 years after implantation. All implants had been inserted into virgin subfascial, extra-pectoral planes. The results add to the important previously described histological findings of Bassetto et al. (Aesthet Plast Surg 34:481–485, 2010). Five distinct layers are identified and reasons for the development of each layer are discussed. Breast capsule around polyurethane implants, in situ for fifteen and 20 years, has recently been obtained and analysed in Brazil, and the histology has been incorporated into this study. After 20 years, the polyurethane is almost undetectable and capsular contracture may appear. These findings contribute to our understanding of polyurethane implant safety, and give reasoning for a significant reduction in clinical capsular contracture rate, up to 10 years after implantation, compared to contemporary silicone implants. A more permanent matrix equivalent to polyurethane may be the solution for reducing long-term capsular contracture.

History

Refereed

  • Yes

Volume

39

Issue number

5

Page range

713-723

Publication title

Aesthetic Plastic Surgery

ISSN

1432-5241

Publisher

Springer

Language

  • other

Legacy posted date

2019-06-24

Legacy Faculty/School/Department

ARCHIVED Faculty of Medical Science (until September 2018)

Usage metrics

    ARU Outputs

    Categories

    No categories selected

    Licence

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC