Anglia Ruskin Research Online (ARRO)
Browse
Banister_et_al_2016.pdf (980.23 kB)

Can Automated Imaging for Optic Disc and Retinal Nerve Fiber Layer Analysis Aid Glaucoma Detection?

Download (980.23 kB)
journal contribution
posted on 2023-07-26, 14:04 authored by Katie Banister, Charles Boachie, Rupert R. A. Bourne, Jonathan Cook, Jennifer M. Burr, Craig R. Ramsay, David F. Garway-Heath, Joanne Gray, Pete McMeekin, Rodolfo Hernández, Augusto Azuara-Blanco
Purpose- To compare the diagnostic performance of automated imaging for glaucoma. Design- Prospective, direct comparison study. Participants- Adults with suspected glaucoma or ocular hypertension referred to hospital eye services in the United Kingdom. Methods- We evaluated 4 automated imaging test algorithms: the Heidelberg Retinal Tomography (HRT; Heidelberg Engineering, Heidelberg, Germany) glaucoma probability score (GPS), the HRT Moorfields regression analysis (MRA), scanning laser polarimetry (GDx enhanced corneal compensation; Glaucoma Diagnostics (GDx), Carl Zeiss Meditec, Dublin, CA) nerve fiber indicator (NFI), and Spectralis optical coherence tomography (OCT; Heidelberg Engineering) retinal nerve fiber layer (RNFL) classification. We defined abnormal tests as an automated classification of outside normal limits for HRT and OCT or NFI ≥ 56 (GDx). We conducted a sensitivity analysis, using borderline abnormal image classifications. The reference standard was clinical diagnosis by a masked glaucoma expert including standardized clinical assessment and automated perimetry. We analyzed 1 eye per patient (the one with more advanced disease). We also evaluated the performance according to severity and using a combination of 2 technologies. Main Outcome Measures- Sensitivity and specificity, likelihood ratios, diagnostic, odds ratio, and proportion of indeterminate tests. Results- We recruited 955 participants, and 943 were included in the analysis. The average age was 60.5 years (standard deviation, 13.8 years); 51.1% were women. Glaucoma was diagnosed in at least 1 eye in 16.8%; 32% of participants had no glaucoma-related findings. The HRT MRA had the highest sensitivity (87.0%; 95% confidence interval [CI], 80.2%–92.1%), but lowest specificity (63.9%; 95% CI, 60.2%–67.4%); GDx had the lowest sensitivity (35.1%; 95% CI, 27.0%–43.8%), but the highest specificity (97.2%; 95% CI, 95.6%–98.3%). The HRT GPS sensitivity was 81.5% (95% CI, 73.9%–87.6%), and specificity was 67.7% (95% CI, 64.2%–71.2%); OCT sensitivity was 76.9% (95% CI, 69.2%–83.4%), and specificity was 78.5% (95% CI, 75.4%–81.4%). Including only eyes with severe glaucoma, sensitivity increased: HRT MRA, HRT GPS, and OCT would miss 5% of eyes, and GDx would miss 21% of eyes. A combination of 2 different tests did not improve the accuracy substantially. Conclusions- Automated imaging technologies can aid clinicians in diagnosing glaucoma, but may not replace current strategies because they can miss some cases of severe glaucoma.

History

Refereed

  • Yes

Volume

123

Issue number

5

Page range

930-938

Publication title

Ophthalmology: Journal of The American Academy of Ophthalmology

ISSN

1549-4713

Publisher

Elsevier

File version

  • Published version

Language

  • eng

Legacy posted date

2017-03-27

Legacy creation date

2017-03-27

Legacy Faculty/School/Department

ARCHIVED Faculty of Medical Science (until September 2018)

Usage metrics

    ARU Outputs

    Categories

    No categories selected

    Keywords

    Licence

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC