Near work-induced transient myopia in Indian subjects

Sivaraman, Viswanathan, Rizwana, Jameel H., Ramani, Krishnakumar, Price, Holly C., Calver, Richard I., Pardhan, Shahina, Vasudevan, Balamurali and Allen, Peter M. (2015) Near work-induced transient myopia in Indian subjects. Clinical and Experimental Optometry, 98 (6). pp. 541-546. ISSN 1444-0938

[img] Text
Accepted Version
Available under the following license: Creative Commons Attribution Non-commercial.

Download (127kB)
Official URL: https://doi.org/10.1111/cxo.12306

Abstract

PURPOSE: The aim was to determine the characteristics of near work-induced transient myopia (NITM) in asymptomatic Indian subjects and the influence of target size and contrast. METHODS: Two studies were conducted: First, 24 myopes and 24 emmetropes viewed four targets (N8 and N12 with 50 and 90 per cent contrasts) placed at 0.2 m for five minutes. The refractive status was assessed objectively, before and after carrying out the near task, with the Grand Seiko WAM-5500 open-field autorefractor under monocular viewing conditions. Second, a different group of 24 myopes and 24 emmetropes viewed a N12 target with 90 per cent contrast for 60 minutes with pre- and post-refractive state measurements repeated as above. NITM was defined as the difference between pre-task and post-task distance refraction. RESULTS: In the first study, myopes demonstrated an initial post-task myopic shift of 0.21 D, whereas emmetropes demonstrated a small hyperopic shift of 0.07 D (p < 0.001). The myopes demonstrated a decay time constant of 6.07 seconds. There was no effect of target size or contrast on the magnitude of the NITM or the decay time constant (p > 0.05). In the second study, myopes showed a NITM of 0.31 D, which was significantly greater than emmetropes (p < 0.001). The myopes demonstrated a decay time constant of 8.16 seconds. CONCLUSION: The magnitude of the NITM was higher in myopes compared to emmetropes for both five minute and 60 minute viewing time. The NITM decayed slightly faster than that found in previous literature for some other ethnic groups. Potential reasons for these findings are discussed.

Item Type: Journal Article
Keywords: decay time constant, myopia, near work‐induced transient myopia, target contrast, target size
Faculty: ARCHIVED Faculty of Science & Technology (until September 2018)
Depositing User: Repository Admin
Date Deposited: 03 Mar 2016 10:29
Last Modified: 31 Jan 2022 09:17
URI: https://arro.anglia.ac.uk/id/eprint/600508

Actions (login required)

Edit Item Edit Item