Cook, Christopher M. and Warisawa, Takayuki and Howard, James P. and Keeble, Thomas R. and Iglesias, Juan F. and Schampaert, Erick and Bhindi, Ravinay and Ambrosia, Alphonse and Matsuo, Hitoshi and Nishina, Hidetaka and Kikuta, Yuetsu and Shiono, Yasutsugu and Nakayama, Masafumi and Doi, Shunichi and Takai, Manabu and Goto, Sonoka and Yakuta, Yohei and Karube, Kenichi and Akashi, Yoshihiro J. and Clesham, Gerald J. and Kelly, Paul A. and Davies, John R. and Karamasis, Grigoris V. and Kawase, Yoshiaki and Robinson, Nicholas M. and Sharp, Andrew S. P. and Escaned, Javier and Davies, Justin E. (2019) Algorithmic Versus Expert Human Interpretation of Instantaneous Wave-Free Ratio Coronary Pressure-Wire Pull Back Data. JACC: Cardiovascular Interventions, 12 (14). pp. 1315-1324. ISSN 1876-7605

[img]
Preview
Text
Published Version
Available under the following license: Creative Commons Attribution.

Download (649kB) | Preview
Official URL: https://doi.org/10.1016/j.jcin.2019.05.025

Abstract

Objectives The aim of this study was to investigate whether algorithmic interpretation (AI) of instantaneous wave-free ratio (iFR) pressure-wire pull back data would be noninferior to expert human interpretation. Background Interpretation of iFR pressure-wire pull back data can be complex and is subjective. Methods Fifteen human experts interpreted 1,008 iFR pull back traces (691 unique, 317 duplicate). For each trace, experts determined the hemodynamic appropriateness for percutaneous coronary intervention (PCI) and, in such cases, the optimal physiological strategy for PCI. The heart team (HT) interpretation was determined by consensus of the individual expert opinions. The same 1,008 pull back traces were also interpreted algorithmically. The coprimary hypotheses of this study were that AI would be noninferior to the interpretation of the median expert human in determining: 1) the hemodynamic appropriateness for PCI; and 2) the physiological strategy for PCI. Results Regarding the hemodynamic appropriateness for PCI, the median expert human demonstrated 89.3% agreement with the HT in comparison with 89.4% for AI (p < 0.01 for noninferiority). Across the 372 cases judged as hemodynamically appropriate for PCI according to the HT, the median expert human demonstrated 88.8% agreement with the HT in comparison with 89.7% for AI (p < 0.0001 for noninferiority). On reproducibility testing, the HT opinion itself changed 1 in 10 times for both the appropriateness for PCI and the physiological PCI strategy. In contrast, AI showed no change. Conclusions AI of iFR pressure-wire pull back data was noninferior to expert human interpretation in determining both the hemodynamic appropriateness for PCI and the optimal physiological strategy for PCI.

Item Type: Journal Article
Keywords: artificial intelligence, coronary physiology, iFR, instantaneous wave-free ratio, percutaneous coronary intervention
Faculty: Faculty of Health, Education, Medicine & Social Care
Depositing User: Ian Walker
Date Deposited: 17 Jul 2019 15:28
Last Modified: 14 Nov 2019 16:07
URI: http://arro.anglia.ac.uk/id/eprint/704563

Actions (login required)

Edit Item Edit Item