Anglia Ruskin Research Online (ARRO)
Browse
Liu_2020.pdf (1.09 MB)

Clinical evaluation of stretchable and wearable inkjet-printed strain gauge sensor for respiratory rate monitoring at different measurements locations

Download (1.09 MB)
journal contribution
posted on 2023-08-30, 17:00 authored by Ala’aldeen Al-Halhouli, Loiy Al-Ghussain, Saleem El Bouri, Haipeng Liu, Dingchang Zheng
The respiration rate (RR) is a vital sign in physiological measurement and clinical diagnosis. RR can be measured using stretchable and wearable strain gauge sensors which detect the respiratory movements in the abdomen or thorax areas caused by volumetric changes. In different body locations, the accuracy of RR detection might differ due to different respiratory movement amplitudes. Few studies have quantitatively investigated the effect of the measurement location on the accuracy of new sensors in RR detection. Using a stretchable and wearable inkjet-printed strain gauge (IPSG) sensor, RR was measured from five body locations (umbilicus, upper abdomen, xiphoid process, upper thorax, and diagonal) on 30 healthy test subjects while sitting on an armless chair. At each location, reference RR was simultaneously detected by the e-Health sensor, and the measurement was repeated twice. Subjects were asked about the comfortableness of locations. Based on Levene’s test, ANOVA was performed to investigate if there is a significant difference in RR between sensors, measurement locations, and two repeated measurements. Bland–Altman analysis was applied to the RR measurements at different locations. The effects of measurement site and measurement trials on RR difference between sensors were also investigated. There was no significant difference between IPSG and reference sensors, between any locations, and between the two measurements (all p > 0.05). As to the RR deviation between IPSG and reference sensors, there was no significant difference between any locations, or between two measurements (all p > 0.05). All the 30 subjects agreed that diagonal and upper thorax positions were the most uncomfortable and most comfortable locations for measurement, respectively. The IPSG sensor could accurately detect RR at five different locations with good repeatability. Upper thorax was the most comfortable location.

History

Refereed

  • Yes

Volume

35

Page range

453-462

Publication title

Journal of Clinical Monitoring and Computing

ISSN

1573-2614

Publisher

Springer

File version

  • Accepted version

Language

  • eng

Legacy posted date

2020-03-03

Legacy creation date

2020-03-04

Legacy Faculty/School/Department

Faculty of Health, Education, Medicine & Social Care

Usage metrics

    ARU Outputs

    Categories

    No categories selected

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC