Anglia Ruskin Research Online (ARRO)
Browse

File(s) not publicly available

Distance word acuity, critical print size and driving vision standards

journal contribution
posted on 2023-07-26, 13:43 authored by Sheila M. Rae, Keziah Latham, Maria F. Katsou
Background: A comparison was made between letter visual acuity and word acuity at distance and between letter acuity and the minimum word size allowing maximum and fluent reading speeds. Methods: Visual acuities were measured at six metres for 120 participants. Letter acuity was assessed with a logMAR layout chart with Sloan letters displayed with Thomson XPert software. A logMAR layout lowercase word chart was created in PowerPoint using the format of the MNRead near chart, with the font and colours found on United Kingdom motorway signs. Distance letter and word acuity, maximum reading speed, critical print size (CPS) and minimum print size for fluent reading were calculated. Results: Word and letter acuities were significantly correlated (p < 0.001) and showed a statistically (p = 0.049) but not clinically significant mean difference of 0.02 ± 0.09 logMAR. Bland–Altman analysis showed that agreement between charts varied depending on acuity level with word acuity better than letter acuity at levels closer to the driving standard of +0.30 logMAR (6/12). Maximum reading speed was achieved from print sizes 1.5 logMAR lines larger than the letter acuity and fluent reading at 80 words per minute from print sizes 0.06 logMAR larger than the letter acuity. Conclusion: These results allow equivalent lowercase print sizes supporting either functional reading or maximum reading speeds to be calculated based on letter chart acuities at distance. Minimum print sizes allowing either functional or maximum reading speeds are more appropriate than threshold word acuities, where groups of words or short phrases need to be identified, such as when driving. Where a driving vision standard of +0.30 logMAR (6/12) exists, a person just meeting the driving standard should be able to read fluently words on signage in lowercase x-heights equivalent to between +0.29 and +0.30 logMAR.

History

Refereed

  • Yes

Volume

98

Issue number

5

Page range

459-463

Publication title

Clinical and Experimental Optometry

ISSN

1444-0938

Publisher

Taylor & Francis

Language

  • other

Legacy posted date

2016-02-26

Legacy Faculty/School/Department

ARCHIVED Faculty of Science & Technology (until September 2018)

Usage metrics

    ARU Outputs

    Categories

    No categories selected

    Licence

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC